Contents :
Guide Specifications Office of the University Architect Engineering Utilities and Construction 27 1533 Coaxial Horizontal Cabling Page 1 of 6 The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary submittals so it is easily found. If we don t see it we will ask you to point it out. Last Update: July 13 2011 PART 1: GENERAL 1.01 SCOPE OF WORK A. 1.02 Work covered by this Section shall consist of furnishing labor equipment supplies materials and testing unless otherwise specified and in performing the following operations recognized as necessary for the installation termination and labeling of horizontal coax infrastructure as described on the Drawings and/or required by these specifications. RELATED SECTIONS A. Division 27 Section 270528 Pathways for Communication Systems. B. Division 27 Section 270543 Underground Ducts and Raceways for Communication Systems. C. Division 27 Section 270553 Identification for Communication Systems. D. Division 27 Section 271116 Communications Cabinets Frames Racks and Enclosures. E. Division 27 Section 271119 Communications Termination Blocks and Patch Panels. F. Division 27 Section 271313 Communications Copper Backbone Cabling. G. Division 27 Section 271323 Communications Optical Fiber Backbone Cabling. H. Division 27 Section 271333 Communications Coaxial Backbone Cabling. I. Division 27 Section 271513 Communications Copper Horizontal Cabling. J. Division 27 Section 271523 Communications Optical Fiber Horizontal Cabling. K. Division 27 Section 271543 Communications Faceplates and Connectors. PART 2: PRODUCTS 2.01 COAX CABLING A. Horizontal Cables (CATV) - Provide CATV cables from PIC outlets in rooms through conduits to skeletals then through skeletals to IDF or BDF. 1. Each CATV cable shall be Type RG-6 18 gauge solid copper center conductor with overall Black PVC jacket CMR rated. 2. Manufacturer shall be Belden #9116R. 3. Where plenum CATV cable is required use Belden #9116P with overall natural Flamarrest jacket CMP rated. 4. New buildings shall utilize plenum cabling in the entire building. Freehafer Hall of Administrative Services 401 S. Grant Street physicalfacilities@purdue.edu West Lafayette IN 47907-2024 Guide Specifications Office of the University Architect Engineering Utilities and Construction 27 1533 Coaxial Horizontal Cabling Page 2 of 6 PART 3: EXECUTION 3.01 TELECOMMUNICATIONS INSTALLATION A. General: 1. 2. The Contractor is instructed to coordinate his efforts with the other tradesmen who may be working within the same vicinity to avoid conflict and lost time. 3. The Contractor is required to supply all necessary tools equipment accessories safety equipment protective clothing etc. as customary for the craft and necessary for the installation. 4. The Contractor shall verify space requirements and locations with Owner before starting cable installations and terminations. 5. The Contractor shall verify the cable type and jacket rating required with a Purdue Information Technology Telecommunications Representative before starting coax installation. 6. 3.02 This Section describes the installation locations for the products and materials as well as methods and Owner s Standards associated with the Telecommunications Installation portions of the Project. These Specifications along with the drawings and other Owner supplied specifications shall be followed during the course of the installation. The Contractor shall verify existing cable fill in skeletal conduit raceway or cable tray system before installation of additional cables so as not to exceed 40% cable fill. Contractor will be responsible for installation of additional skeletal conduit raceway or cable tray where additional cables to be added will exceed the 40% cable fill. See cable fill attachment 3.01 Attachment #1. SKELETAL AND EMPTY STATION CONDUITS A. B. 3.03 Provide a nylon pull cord in each empty conduit to facilitate future installation of cables. Provide a nylon pull cord in each empty conduit and extended in raceway to openings for PIC faceplates to facilitate future installation of cables. HORIZONTAL COAX CABLING A. B. Contractor is responsible to obtain and follow installation instructions for Belden products for correct termination and coax management of cables on respective products. C. Owner to provide future taps splitters and amplifiers. D. 3.04 The horizontal coax cabling will be terminated at the IDF or BDF on a wall designated by a Purdue IT Telecommunications Representative. All coax terminations shall be done with compression style coax connectors. GENERAL COAX INSTALLATION A. Cable lengths within boxes shall be adequate to permit instal
- Rating :
- Get Online Jobs!
- File Type : .pdf
- Length : 6 pages
- File Size: 89.3 kb
- Virus Tested : No
- Verified : 2012-07-26
- Source: www.purdue.edu
INFO HASH : 024a02029cf071fefd0ddd63029f08f12e6ec4ba
blog comments powered by Disqus

Download now